Repair instead of buying new.
Brand-independent repair of ultrasound probes — from cosmetic work to a full overhaul with crystal replacement. 24h express when spare parts are available, loan probe for the duration of the repair. From Graz, for clinics across Europe. We only start the repair once you have approved the quotation.
Repair advisor.
Five questions about your probe — at the end you get an initial assessment and a completed enquiry form.
The following questions follow your choice — you only see what applies to this probe type.
The manufacturer is enough to start. Model and serial number speed up the spare-part check considerably.
Multiple choice. The more complete, the more precise the assessment — if in doubt choose “Unclear”.
This tells us whether to schedule express handling and reserve a loan probe.
The next step only needs your contact details — everything else is already filled in. The enquiry is non-binding: we analyse the probe, send a quotation and only repair after your approval.

Every probe deserves a second life.
Our experienced in-house team of technicians repairs mechanical probes from every manufacturer — from cosmetic refurbishment to a full overhaul with crystal replacement. To ISO standards, with spare parts of the best quality.
In contact with all manufacturers, connected worldwide.
On full overhauls including crystals.
100 % recyclable packaging material — together for a green moon-iverse.
We will not sell you
a new probe.
We repair the one you have — independent of brand, including older equipment sold under earlier manufacturer names.
For every manufacturer, the model designations we work on and the matching fault patterns.
All manufacturer and product names mentioned serve solely to describe the devices we repair. There is no business relationship with the manufacturers named.
Six probe types.
Five repair levels.
A transparent price structure — from cosmetic work to “Refurbished by MOONS”.
Standard & matrix standard probes 24h express possible
Wireless probes 24h express possible
3D/4D & matrix 3D/4D probes 24h express possible
TEE & matrix TEE probes on request
Flexible endoscopes on request
Ultrasound endoscopes on request
Every repair is individual and quoted on request — depending on the probe model and its condition. After the analysis you receive a transparent quotation. Additional services: disinfection to ISO standards, collection across Europe, 24h express service.
Why probes fail —
and how we find it.
Studies regularly find every fourth to every third probe in clinics to be faulty. Very few of them look broken.
Quality-assurance studies report failure rates between 25 and almost 40 percent of the probes tested. By far the most common finding is delamination of the lens — a separation within the layer structure that degrades the image long before anything looks visibly broken. And because the probe is the most heavily used part of the system, the majority of all ultrasound failures come from the probe, not from the device.
Image dropout & shadowing
Technically: element failure, in English dropout. A focal gap in the reverberation image, typical after a drop or a perforation. It can also distort Doppler velocities.
Cloudy image with no visible damage
Usually delamination or an inhomogeneous lens. The single most common finding of all — and the reason why regular testing achieves more than looking.
Lens crack & lens wear
Safety-relevant: a crack in the lens is a cross-contamination risk. Alcohol-based disinfection dries the lens out further.
Cable break & strain relief
Depending on the probe, the cable contains more than a hundred fine wires. A break causes crosstalk and artefacts that look like element failure — while the housing looks intact.
Connector and pin faults
Can be narrowed down in-house: if the probe shows the same image on another port of the device, the connector is not the cause.
Fluid ingress
Take the probe out of service immediately. Fluid that has entered causes corrosion throughout the probe and is an electrical risk.
Mechanics in 3D/4D
Motor blockage, gear wear, bubbles in the coupling fluid, cracks in the cap — plus model-specific initialisation errors.
Bite marks on TEE probes
Cuts in the bending rubber, crushed shafts, corrosion in the articulation mechanics. TEE probes additionally require a leakage test.
Measure first. Then repair.
Every probe goes through the same chain before we issue a quotation — and once more before it goes back.
The results are recorded in the test report that comes back with the probe — ready to file with your device documentation.
How it works.
From the enquiry to the repaired probe — across Europe.
Not only probes:
medical batteries.
The same workshop, the same logic — repair instead of replace, with battery development inside the group.

We repair medical battery packs — all technologies including lithium and lithium-ion, by our own team of technicians, to ISO standards and with high-quality spare parts from the original manufacturers. Here too you save up to 70 % compared with buying new.
We test the pack and come back to you with a quotation.
Cells, electronics and housing — in-house in Graz.
So the device is ready for use again quickly.
Proper disposal of the replaced cells.
All fault patterns at a glance
What comes back
with your probe.
A repair is only as good as its evidence — which is why every probe comes with a report.
A test report with every repair
Fault pattern, work carried out, parts fitted and final test — ready to file with your device documentation. Operators are obliged to document maintenance; the report is designed for that.
No repair without your approval
After the analysis you receive a written quotation. We only begin work once you approve it — no costs arise that you did not expect. If you decline, we send the probe back.
You are free to choose
In Germany and Austria, the regulations for operators of medical devices do not tie maintenance to the manufacturer. Any business that meets the professional requirements may be commissioned — and whoever assesses the probe professionally must be free from instructions in doing so. Comparable rules apply in most EU countries. Manufacturer specifications have to be taken into account, but they do not establish a service monopoly.
Officially authorised, verifiable
Trade licence for the manufacture and reprocessing of medical devices and for servicing imaging diagnostic equipment — GISA number 33592718, City of Graz. Viewable in the public register.
Battery development in-house
Through the MOONS Group, AccuPower — a developer of customer-specific battery packs since 1998 — belongs to the group. For wireless probes and medical batteries we do not work with off-the-shelf parts.
Loan probe during the repair
So your department keeps working, we provide a loan probe for the duration of the repair, subject to availability.
Hygiene in both directions
You hand over the probe cleaned and disinfected, we send it back reprocessed and disinfected. Packaging material fully recyclable.
80 kg less CO₂ per repair
100 % recyclable packaging material and a photovoltaic system on our own offices — together that gives a saving of up to 80 kg of CO₂ per probe repair compared with buying new.
What clinics ask us.
The twelve questions that come up before almost every order — answered briefly and without sales prose.
What does repairing an ultrasound probe cost?
Every repair is calculated individually, because the effort depends on the probe model and its condition. After the analysis in Graz you receive a written quotation. Compared with buying new you usually save up to 70 percent. We only begin work once you approve the quotation.
Next stepSend an enquiry — answer within one working day→How long does a probe repair take?
On arrival the probe goes through our test chain, after which you get the quotation — we reply to your enquiry within one working day. The repair itself depends on the scope and on the availability of spare parts. If the parts are there, a 24h express is possible. For the meantime we provide a loan probe subject to availability.
Next stepThe repair levels in detail→May I have my probe repaired outside the manufacturer?
Yes. Maintenance of medical devices is not tied to the manufacturer; any business meeting the professional requirements may be commissioned. Whoever assesses the probe professionally must be free from instructions in doing so. Manufacturer specifications must be taken into account but do not establish a service monopoly. Whether a running device warranty or a full-service contract contains its own rules is stated in that contract — best checked beforehand.
Next stepSend an enquiry — answer within one working day→Which manufacturers do you repair?
We work brand-independently: GE Healthcare, Philips including the legacy stock of ATL and HP, Siemens Healthineers and Acuson, Canon and Toshiba, Esaote, Fujifilm with Hitachi, Aloka and Sonosite, Mindray, Samsung with Medison and SonoAce, SonoScape, Alpinion, BK Medical, Olympus for endoscopes and Butterfly. In total 915 model designations are on file. If your probe is not among them, ask anyway.
Next stepSend an enquiry — answer within one working day→Do I get a loan probe during the repair?
Subject to availability we provide a loan probe for the duration of the repair so your department keeps working. State the need right in the enquiry form and we reserve it together with the scheduling.
Next stepThe repair levels in detail→What do the five repair levels mean?
Level 1 is cosmetic work and partial cable repairs. Level 2 covers housing, strain relief, connector and pins. Level 3 is the coating with partial refurbishment. Level 4 are package repairs combining several areas. Level 5 is the full overhaul including crystal replacement with twelve months warranty. 3D/4D probes have four levels; on TEE probes and endoscopes the highest stage is called Refurbished by MOONS.
Next stepAll fault patterns at a glance→How do I send the probe in?
You fill in the enquiry form — fastest through the repair advisor, which prepares it for you. On request we organise collection across Europe. Enclose the printed form with the shipment and your case goes straight to the technicians without queries.
Next stepAll manufacturers and model designations→What happens if the repair is not worthwhile?
Then we tell you. You receive the assessment with the quotation and decide. If you decline, we send the probe back. We repair nothing without your approval, and no costs arise that you did not expect.
Next stepSend an enquiry — answer within one working day→Do I get a test report?
Yes, with every repair. It states the fault pattern, the work carried out, the parts fitted and the final test — ready to file with your device documentation. Operators are obliged to document maintenance; the report is designed for that.
Next stepSend an enquiry — answer within one working day→Is there a warranty on the repair?
On full overhauls including crystal replacement we give twelve months warranty. On smaller repair levels the warranty follows the scope of the work; what applies is stated in the quotation.
Next stepSend an enquiry — answer within one working day→Do you also repair endoscopes and medical batteries?
Yes. Flexible endoscopes — gastroscopes, colonoscopes, bronchoscopes and duodenoscopes — and ultrasound endoscopes for endosonography are repaired just like medical battery packs of all technologies including lithium and lithium-ion. Battery development sits inside the group with AccuPower.
Next stepSend an enquiry — answer within one working day→Does the probe have to be disinfected before I send it?
Yes. The probe is handed over cleaned and disinfected, which you confirm in the enquiry form with the hygiene declaration. It comes back from us reprocessed and disinfected, documented to ISO standards on request.
Next stepSend an enquiry — answer within one working day→Enquiry form
probe repair.
The more precise your details, the faster the quotation — we reply within one working day. Phone: +43 316 22 81 10
Stay up to date.
News from probe repair: procedures, probe types and dates — straight to your inbox.
Choose your language
Choose your language · Choisissez votre langue · Scegli la lingua · Elige tu idioma · Kies uw taal · Wybierz język